Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Braz J Cardiovasc Surg ; 33(2): 189-193, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29898150

RESUMO

INTRODUCTION: The great saphenous vein is widely used as a graft in coronary artery bypass grafting surgery. Complications due to saphenous vein harvesting can be minimized when using ultrasonography mapping and marking. OBJECTIVE: To analyze by clinical trial the use of vascular ultrasonography to map the saphenous vein in coronary artery bypass grafting to determine viability and dissection site. METHODS: A total of 151 consecutive patients submitted to coronary artery bypass surgery with the use of the great saphenous vein as a graft were selected for this prospective study. They were divided into two groups: Group 1 - 84 patients were submitted to ultrasonographic mapping and marking of the saphenous vein; Group 2 - 67 patients had saphenous vein harvested without any previous study. Both groups were coupled with follow-up on the 1st, 5th and 30th postoperative days. Primary endpoints were need for incision of the contralateral leg and wound complications within 30 days. RESULTS: Both legs had to be incised in 6 (8.95%) patients from Group 2 (P=0.0067). Wound complications occurred in 33 (23.4%) patients within 30 days, 21 (35%) from Group 2 e 12 (14.8%) from Group 1 (OR 3.095, 1.375-6.944, CI 95%, P=0.008). Within 30 days there were 4 (2.8%) deaths, all in Group 2 (P=0.036). CONCLUSION: The use of vascular ultrasonography for mapping of the great saphenous vein in coronary artery bypass surgery has properly identified and evaluated the saphenous vein, significantly reducing wound complications and unnecessary incisions. It would be advisable to use this noninvasive and easy to use method routinely in coronary artery bypass surgery.


Assuntos
Ponte de Artéria Coronária/métodos , Veia Safena/diagnóstico por imagem , Veia Safena/transplante , Coleta de Tecidos e Órgãos/métodos , Ultrassonografia Doppler/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Infecção da Ferida Cirúrgica , Fatores de Tempo , Coleta de Tecidos e Órgãos/efeitos adversos , Ultrassonografia Doppler/efeitos adversos
2.
Rev. bras. cir. cardiovasc ; 33(2): 189-193, Mar.-Apr. 2018. tab, graf
Artigo em Inglês | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-958396

RESUMO

Abstract Introduction: The great saphenous vein is widely used as a graft in coronary artery bypass grafting surgery. Complications due to saphenous vein harvesting can be minimized when using ultrasonography mapping and marking. Objective: To analyze by clinical trial the use of vascular ultrasonography to map the saphenous vein in coronary artery bypass grafting to determine viability and dissection site. Methods: A total of 151 consecutive patients submitted to coronary artery bypass surgery with the use of the great saphenous vein as a graft were selected for this prospective study. They were divided into two groups: Group 1 - 84 patients were submitted to ultrasonographic mapping and marking of the saphenous vein; Group 2 - 67 patients had saphenous vein harvested without any previous study. Both groups were coupled with follow-up on the 1st, 5th and 30th postoperative days. Primary endpoints were need for incision of the contralateral leg and wound complications within 30 days. Results: Both legs had to be incised in 6 (8.95%) patients from Group 2 (P=0.0067). Wound complications occurred in 33 (23.4%) patients within 30 days, 21 (35%) from Group 2 e 12 (14.8%) from Group 1 (OR 3.095, 1.375-6.944, CI 95%, P=0.008). Within 30 days there were 4 (2.8%) deaths, all in Group 2 (P=0.036). Conclusion: The use of vascular ultrasonography for mapping of the great saphenous vein in coronary artery bypass surgery has properly identified and evaluated the saphenous vein, significantly reducing wound complications and unnecessary incisions. It would be advisable to use this noninvasive and easy to use method routinely in coronary artery bypass surgery.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Veia Safena/transplante , Veia Safena/diagnóstico por imagem , Ponte de Artéria Coronária/métodos , Ultrassonografia Doppler/métodos , Coleta de Tecidos e Órgãos/métodos , Complicações Pós-Operatórias , Infecção da Ferida Cirúrgica , Fatores de Tempo , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia Doppler/efeitos adversos , Estatísticas não Paramétricas , Coleta de Tecidos e Órgãos/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...